Meet the standards: IEC60068-2-66, JESD22-A102-C; JESD22-A110-B; JESD22-A118; GB/T 2423.40-1997

Product name: PCT high pressure aging test chamber is also called PCT accelerated life aging chamber, PCT accelerated aging test chamber

Humidification water temperature control method:

When the temperature rises to the temperature where dew water is easy to condense inside the sample, the temperature of the water is automatically increased, so that the temperature of the heated water is about 30 degrees lower than that in the test chamber. After the test is over, the test chamber is naturally cooled to reduce the internal pressure to 0.01 mp, then exhaust and drain.

Humidity saturation control:

Use a humidifying heater to control the temperature in the test chamber. When the test is over, the test chamber is naturally cooled to reduce the internal pressure to 0.01, and then the exhaust gas and humidified water are used to stay.

Manufacturer: Dongguan Huanyi Instrument Technology Co., Ltd.

PCT accelerated aging test chamber technical parameters

1. Interior size: 300×450 mm (φ×D) circular test chamber.

2. Exterior size: 700×900×650 mm(W×H×D)

3. Interior material: SUS 316# stainless steel plate material.

4. Exterior material: high-grade paint.

5. Temperature range: 100℃132℃. (Saturated steam temperature).

6. Humidity range: 100%RH (saturated vapor humidity).

7. Pressure range (pressure on the gauge): 0.0Kg/cm22.0Kg/cm2 control point pressure (safety pressure capacity 3.5Kg/cm2).


8. Time range: 0 ~ 999 hours adjustable.

9. Temperature distribution: ≤± 2.0℃.

10. Heating time: room temperature ~ 132℃ within about 40 minutes. (Control point temperature).

11. Pressurization time: 0.0Kg/cm2 ~ 2.0Kg/cm2 within about 45 minutes (control point pressure).

12. Control object: microcomputer+P.I.D.+S.S.R automatic calculation to control the saturated steam temperature.

13. Control method: Microcomputer PID control.

14. Control accuracy: ≤± 0.5℃.

15. Resolution accuracy: 0.1℃.




Prev New Next New

Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top