What structures and equipment are needed to meet the ANSI/AHAM AC-1-2006 purifier environmental testing chamber to meet the requirements?
1. Meet the standards: ANSI/AHAM AC-1-2006 Performance Test Method for Portable Household Electric Indoor Air Purifiers
2. Manufacturer: Dongguan Huanyi Instrument Technology Co., Ltd.3. Cabin test room structure (equivalent alternative materials and equipment are allowed to be used)
Test chamber dimensions: Interior dimensions 10 ½x12x8 feet, 1008 cubic feet (3.2x3.7x2.4 meters, 28.5 cubic meters)
Note: Silicone caulk shall not be used in the test chamber.
Frame: Standard construction 2 x 4 inches (5.1 x 10.2 cm), floor line sealed inside and out with caulk
Walls: ½ in. (1.3 cm) siding, lower 3/8 in. (0.9 cm) plywood
Flooring: Seamless full-width linoleum or vinyl flooring with smooth surface
Filtration: High-efficiency particulate air (HEPA) filter that effectively removes 0.5 micron DOP cigarette smoke (1000cfm).
Pre-filter: 60% ASHRAE efficiency; Coarse filter: 20-30% ASHRAE efficiency.
Paint: white washable semi-gloss latex paint
Ceiling Fan: 3-blade 36-inch (0.91m) ceiling fan, 359RPM, No. 4C852, 0.5A, 120V, 28 lbs (12.7
Kilogram). Product of W.W. Grainger Company.
Recycling electric and fan: 750 cfm (21.5 m3/m) fan, 4 in. (10.2 cm) WG, 3/4 HP motor, 3-phase 208V
Recirculation fan location: The center of the recirculation fan motor is 60 inches (1.5 meters) from the floor and the fan is 15 inches (0.4 meters) from the rear wall.
Stand: Height: 29.25 inches (0.74 meters) above the floor
Desktop dimensions: 14 x 22 x 1 inch (0.36m x 0.56m x 0.03m)