VOC Emission Test Chamber
Product description:
VOC emission test chamber can provide standard testing environment such as temperature humidity, air exchange rate and airflow to simulate real indoor environment to test the pollutant release rate and release properties of various indoor materials and products.
- Product Details
Standards:
ISO16000-9 |
Indoor air- Part 9: Determination of the emission of volatile organic compounds from building products and furnishing-Emission test chamber method |
GS97014-3 |
BMW Method (Determination of VOCs from components, semifinished products and materials) |
PN 780 |
Porsche Method (Interieur–Emission behavior) |
PV 3942 |
Volkswagen Method (Determining organic emissions from components for the passenger compartment of motor vehicles. Emission test) |
ISO 12219-4 |
Meets all requirements of ISO 12219-4 (Determination of VOCs from vehicle interior parts and materials ) – with the exception of the chamber size |
ASTM D5116-2017 |
Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ASTM D6670-2018 |
Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products |
ISO 16000-9-2006 |
Indoor air- Part 9: Determination of the emission ofvolatile organic compounds from building products and furnishing-Emission test chamber method |
ISO 28360-2007 |
Information technology -Office equipment-Determination of chemical emission rates from electronic equipment |
DIN EN 16516-2018 |
Building products - Evaluation of the release of hazardous substances - Determination of emissions to indoor air |
EN717-1 |
Wood-based panels- Determination of formaldehyde release- Part 1: Formaldehyde emission by the chamber method |
GB I8580 -2017 |
Indoor decorating and refurbishing materials- Limit of formaldehyde emission ofwood-based panels and finishing products |
GB 18587-2001 |
Interior Decoration Materials-Carpet, Carpet Backing and Carpet Adhesive Hazardous Substance Release Limits |
Technical Parameters
Volume(m³) |
1m³ |
Outer Dimension (mm) |
1550*1760*1960(W*D*H) |
Internal Dimensions (mm) |
W850*D1100*H1080(Or customized bycustomer) |
Gate (door hole) |
850*1080mm(W*H) |
Observation window |
370*540mm(W*H) |
Temperature |
15~45℃ Adjustment accuracy:±0.5℃ |
relative humidity |
(20~85)%RH. Adjustment accuracy:±3%RH. |
Pressure |
10±5Pa |
Air replacement rate |
0.2m3~2.5m3/h(ventilation rate 0.2~2time/H) Adjustment accuracy: ventilation ±1% |
Face Velocity |
The air horizontal velocity is maintained at (0.1-1.0) m/s and the accuracy is less than 0.05 m/s. |
Closed |
Static Leakage Rate:Leakage rate <1× m3/min at relative pressure of 1KPa |
Detection recovery rate |
>85%,The recovery test was carried out with three reference materials of toluene, n-dodecane and four phenyl Cyclohexene in a given amount. Provide the recovery test data of the third party (CNAS certification) testing institutions. |