Test steps of bag method sampling cabin for interior parts
Product Name: Bag-style sampling cabin for interior parts
Meet the standard: CVTC 54072—2015 "Test Method for Volatile Organic Compounds and Aldehydes and Ketones in Vehicle Interior Parts (Bag Method)"
1. Test procedure
1.1 Bag-style sampling cabin for interior parts Blank cleaning of sampling bag
1.2 Set the temperature of the walk-in high and low temperature test chamber to 80 ℃, open the door and turn on the gas circulation for 30 minutes, and close the door.
1.3 Bag-style sampling cabin for interior parts Cut the gas sampling bag to be cleaned, put the sampling bag inside out, put it into the test box, reopen the door after heating (10-12) h, and replace the gas in the box for 30 minutes.
1.4 Turn the gas sampling bag over, close the door, and continue heating (2~3) h.
1.5 Take out the gas sampling bag, turn the inner surface back, and seal the gas sampling bag with a sealing machine.
1.6 Bag-style sampling cabin for interior parts Use a diaphragm vacuum pump to evacuate the gas in the gas sampling bag, and observe its air tightness (a certain amount of nitrogen can be filled, and after 2 hours, observe whether the sampling bag is significantly reduced to determine the air tightness of the sampling bag).
1.7 Use high-purity nitrogen to replace the gas sampling bag, fill it with high-purity nitrogen about 50% of its volume, and then extract the gas. Repeat the operation 3 times.
1.8 Accurately fill in 50% high-purity nitrogen, heat at 65 ℃ for 2 h ± 10 min, use TENAX tube to capture benzene and DNPH tube to capture aldehydes. The capture conditions are shown in the table.
1.9 Verify that the bag is blank on the computer, and all individual substances are required to be less than the detection limit of the method.
1.10 If not satisfied, repeat the above steps.