Specification for construction of air disinfectant microbial negative pressure aerosol chamber
The air disinfectant microbial negative pressure aerosol chamber is used to test the sterilization performance of air disinfectants. The current epidemic situation is repeated, and there are many bacteria and viruses in the air. It is necessary to use air disinfectants for disinfection. Whether the disinfection performance of air disinfectants is good or not can be detected by using a microbial negative pressure aerosol chamber.
air disinfectant microbial negative pressure aerosol chamber requirements:
1. The main purpose of microbial negative pressure aerosol chamber
Mainly used for testing household and similar air purifiers, etc. The testing items include:
1) Purification efficiency or removal rate;
2) Clean air volume;
3) Purification efficiency;
4) Input power or standby power;
5) Ozone increase, TVOC increase, PM10 increase, etc.
Remarks: The range of test substances includes: particulate matter (cigarettes), gaseous pollutants (formaldehyde, ammonia, benzene, etc.), microorganisms (natural bacteria)
Technical parameter:
1) Temperature adjustment range: (20~ 30)℃
Adjustment accuracy: +2℃
Measurement accuracy: +0.1℃
2) Relative humidity adjustment range: (40 ~ 60)%RH
Adjustment accuracy: +5%RH
Measurement accuracy: +1%RH
3) Air tightness: the number of air changes is less than 0.05h-1.
4) The background concentration of particles ≥ 0.3 μm in the cabin is 500 particles/L.
5) Equipment Model: Huanyi Instrument HYKJ-20
The above is the explanation of some technical parameters of the air disinfectant microbial negative pressure aerosol chamber. If you want to know more about the test, please visit the official website of "Environmental Instrument".