3m³ purifier CCM test chamber (stainless steel )
This 3m³ purifier CCM test chamber is mainly used for the limited space
device of the purifier's ability to remove target pollutants in the air. It can
be used for CCM test equipment for the cumulative purification capacity
of specific pollution.
- Product Details
ANSI AHAM AC-1-2006 |
Test Method for Performance of Household Electric Power Cords or Indoor Air Cleaners |
AHAM AC-1-2018 |
Method for Measuring Performance of Portable Household Electric Room Air Cleaners |
GB/18801-2015 |
Air Purifier |
GB/18803-2002 |
Indoor Air Quality Standard |
IEC 62301:2005 |
Measurement of standby power in household appliances EPA Energy star United States Environmental Protection Agency Energy Star |
GB 4706.45-2008/IEC 60335-2-65:2005(Ed2.0) |
Electrical safety for household and similar purposes - Particular requirements for air purifiers |
Product structure:
1. Stirring fan
2. Test prototype
3. Air filter
4. Air supply valve
5. Exhaust valve
6. Pollutant detection device
7. Pollutant generating device
8. Sampling port and sample feeding port
9. Airtight door
10. Air-conditioning supply air (and air supply when exhausting)
11. Air conditioning return air (and exhaust air)
Basic test items
1. Smoke CADR test and analysis system
Referring to the AHAM AC-1-2018 standard, test the CADR value of smoke, and intuitively evaluate the
purification performance index of the purifier for particulate matter (including PM2.5).
2. Formaldehyde purification efficiency test
Test the formaldehyde removal efficiency in a 3 cubic meter test chamber for 1 to 6 hours
3. VOC purification efficiency test
Test the removal efficiency of VOC (in toluene) for 1 to 6 hours in a 3 cubic meter test chamber