Precautions and safety measures during the use of cold and hot impact test chamber
Cold and hot impact test chamber mainly for electronic parts, industrial materials, finished products in the R & D production, testing each link of high and low temperature sudden impact to provide rapid temperature change test conditions, suitable for electronic appliances, communications, chemical, hardware, rubber, toys, materials and other industries. Controller panel standard with RJ45 network interface cold and hot impact chamber, can obtain IP address remote control, even if you are not next to the machine, you can also on the computer for real-time operation, monitoring, history curve playback, program editing, FTP upload download, remote value/program control and other functions.
The user must read the instruction manual before using the three-chamber impact test chamber, and operate correctly and safely according to the content. The following points should be noted:
1: Operation sequence to protect personal safety
Two chamberes of impact chamber for blue up and down mobile, running is prohibited to open the door to access samples.
Open the door to access the sample only after the confirmed shutdown (power failure) state.
The lead of the test line must be led through the test hole at the top of the test chamber, otherwise the test line will be pulled off.
Two: Safety measures to protect the sample
During each test, it is necessary to check whether the set value of temperature and humidity is within the maximum allowable range of the sample, otherwise the sample may be damaged by too high or too low temperature.
The device has the function of temperature deviation protection.
When the actual measured temperature is higher than the set temperature or lower than the set temperature, the heating is automatically cut off or the exhaust valve is opened to prevent further temperature rise or decrease of the test product damage.
Three: other matters needing attention
High temperature impact during operation or immediately open the door after the operation, pay special attention to the risk of blowing out high temperature gas in the chamber.
Open the door immediately when the operation is over 55℃. All substances in the chamber are in a high temperature state. Contact with these things may burn your body.
Open the door immediately when the operation is under 0℃ or at the end of the operation. All materials in the chamber are in a low temperature state. Contact with these things may cause frostbite.