Power saving tips for constant temperature and humidity test chamber

Date: Dec 25,2020 Views: 458

1. Placement

The proper placement of the constant temperature and humidity test box is also one of the important factors affecting electricity consumption. Generally, put the device in a cool and ventilated place, avoid direct sunlight, and leave proper space on the top, front, back, left, and right of the device to allow the device to dissipate heat. Because the equipment itself generates heat during operation, the high ambient temperature will increase the power consumption of the test.

2. Check the tightness

Regardless of whether the equipment is in operation, check whether the sealing strip of the test chamber is sealed regularly. If the sealing strip is deformed, it will affect the tightness of the sealing and cause the leakage of air-conditioning, thereby increasing the power consumption of the equipment. If it is severely deformed or suspected of falling off, it should be repaired and replaced in time.

3. constant temperature and humidity test chamber Defrost regularly

Generally, after using for a period of time, the equipment will frost and freeze. If it cannot be defrosted regularly, it will not only affect the refrigeration effect, but also increase the power consumption during use, and may even damage the compressor. Therefore, when the thickness of the frost exceeds 7cm, it should be defrosted.

4. constant temperature and humidity test chamber Reduce the number of door openings and closings

The principle of the test equipment is the same as that of the refrigerator. Every time the door is opened, cold air will leak out and hot air will enter the box, so that the compressor must be operated again for cooling. Therefore, try to reduce the number and time of opening the door when accessing the samples, and the speed of opening and closing the door should be fast, and the angle of opening the door should be as small as possible.

5. Clean regularly

Regardless of the equipment, it must be maintained and cleaned regularly. The constant temperature and humidity test chamber is no exception. The surface of the compressor and condenser is recommended to be cleaned every two to three months. The more dust, the worse the heat dissipation effect and the greater the power consumption. Note that you must cut off the power when cleaning, and wipe it with a damp cloth before it can run.




Prev New Next New

Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top