New tank type temperature impact test box technical specification
(Circle Instrument) Tank Temperature Impact Test Chamber Studio Volume (L): 2.6 4.5
Sample box size (mm): 120 × 120 × 180 150 × 150 × 200
Dimensions in the tank (mm): 250 × 350 × 400 280 × 380 × 420
High temperature tank temperature range: +60 ° C ~ +200 ° C
Low temperature tank temperature range: -80 ° C ~ 0 ° C
Liquid impact temperature -40°C/-65°C~0°C/+60°C+150°C
Tank conversion time: ≤10s
Temperature fluctuation: ±0.5°C~±1.0
Temperature uniformity ±0.5°C~±2.0
Temperature deviation ±0.5°C~±2.0
Working mode: automatic mechanical suspension moves up and down to the high and low temperature tank
Housing material: cold rolled steel powder
Liner material: SUS316
Insulation material: polyurethane foam
Refrigeration unit: semi-closed refrigeration unit
Cooling method: water cooling
Safety device: over temperature protection Compressor lack of oil / over pressure / overload protection Fan overload protection Power failure protection Heater short circuit protection
Optional accessories: remote monitoring of computers and software printers added shelves special sample holders