What should you pay attention to when installing a constant temperature and humidity test chamber? Dongguan Huanyi Instrument Co., Ltd. will explain the issues that are easily overlooked:

1. The placement location should consider the heat dissipation of the equipment and the ease of inspection and maintenance of the equipment.

2. The bottom of the chamber is a refrigeration system, which has a large amount of heat. Therefore, when installing, there should be a distance of at least 60 cm between the chamber body and the wall and any other chambers to maintain ventilation. ,


3. The power supply circuit and drain pipeline should be as short as possible.

4. The equipment should be kept away from dirty and dusty places, environment temperature: 5℃~+30(average temperature within 24 hours 30), environment humidity: 85%RH, the chamber can only get the best results in this environment Best and most stable operation. Otherwise, it may cause the constant temperature and humidity test chamber to cool down slowly or fail to meet the requirements of low temperature, and the temperature and humidity control cannot be very stable.

5. Do not place any sundries on the top of the constant temperature and humidity test chamber to avoid heavy objects falling and causing personal injury and property damage.

6. The maximum inclination of the platinum equipment should be below 30°, and the machine must be firm to prevent the machine from falling down, crushing or smashing the human body and damaging property.

The small details that need to be paid attention to in the operation of the ring instrument constant temperature and humidity test chamber are as follows:

1. To ensure safety, it is recommended not to place electrical sockets, stabilized power supplies and other electrical appliances on the equipment table; also do not use electrical appliances inside the equipment to avoid electromagnetic interference or other accidents.

2. Don't put it in a damp or splashy place. The splashed water and dirt should be wiped clean with a soft cloth in time.

3. Once the constant temperature and humidity chamber starts to operate, you must not directly touch the surface of the freezer with your hands, especially if it is touched with water, otherwise it may stick to the surface of the equipment.

4. When the power is cut or cleaned, the power plug should be unplugged, and the power should be turned on again after maintaining an interval of at least five minutes to prevent damage to the compressor due to continuous starting.

5. It is strictly forbidden to disassemble or modify the equipment without authorization, and it is forbidden to damage the refrigeration pipeline. In the event of a malfunction, it must be repaired by professional personnel.

6. Do not store or use gasoline and other flammable materials near the equipment to avoid fire.

Huanyi Instruments specializes in the production of constant temperature and humidity test chambers, high and low temperature test chambers, high and low temperature and low pressure environmental test chambers, and high and low temperature humidity and heat alternating test chambers.




Prev New Next New

Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top