Phone : +86 0769-83482055 / +8615338361334 Email: dg@huanyi-group.com
facebook twitter linkedin google+ printerest
You are here: Home > Technical Literature > How to measure paint VOC in voc discharge tank?

How to measure paint VOC in voc discharge tank?

Date: May 27,2022 Views: 323

To measure the VOC release of paint, we will use the VOC discharge chamber. Next, the editor of the huanyi instrument will briefly introduce how to use the voc discharge tank to measure the VOC release of the paint.

 

The test process of the VOC release amount of the coating:

 

A. Preparation for the test

Test Sample: Paint Sample

Test equipment: voc discharge tank

Equipment model: HYV-1000

Reference Standard: GB/T 37884-2019 Determination of Volatile Organic Compounds (VOC) Release in Coatings

 

B. The test process:

1. Penetration test of adsorption tube: Sampling with two adsorption tubes in series. If the amount of target volatile organic compounds detected in the latter adsorption tube is lower than the detection limit, it is considered that the adsorption tube has not penetrated.

 

2. Use a flowmeter to calibrate the constant-current sampler before sampling, and adjust the sampling flow of the constant-current sampler so that it is less than 80% of the air intake of the environmental test chamber, and the adsorption tube does not penetrate.

 

3. Select an appropriate sampling volume to ensure that the test results are within the concentration range of the standard curve. The maximum sampling volume should not exceed 10% of the tank capacity. Record the sampling time, sampling flow, temperature and atmospheric pressure at the sampling location.

 

4. After sampling, remove the adsorption tube, seal the two ends of the adsorption tube and make a mark, then put it in a sealed container and measure it within 7 days. Storage of adsorption tubes after sampling shall be carried out in accordance with the manufacturer's requirements.

 

If you don't know what kind of voc discharge tank is suitable for your product for testing, you can visit the official website of "Huanyi Instrument" and consult our customer service staff.




Prev New Next New

Contact us

Telphone: +86 0769-83482055 / +8615338361334

Fax: +86 0769-83482056

Email: dg@huanyi-group.com

Add: Building 2, No. 3, Longkeng Xingye Road, Dongkeng Town, Dongguan,China

google+ twitter facebook printerest linkedin
Copyright 2018 by Dongguan Huanyi Instrument Technology Co., Ltd. All rights reserved. Powered by Onepound
Online Service
Top