Dehumidification capacity laboratory of dehumidifiers
The dehumidification capacity laboratory of dehumidifiers is used to test whether the dehumidification capacity of dehumidifiers in the working state meets the requirements.
- Product Details
Meet the standard: GB/T 19411-2003
Requirements for the dehumidifier dehumidification test laboratory:
1. The size of the test room should be such that the minimum distance between the dehumidifier and the surrounding walls is not less than 1m, and the minimum distance from the air outlet to the wall is not less than 1.8m. The test device should be able to simulate the actual working state of the dehumidifier.
2. The air circulation in the test room should be such that the wind speed at 1m away from the dehumidifier does not exceed 0.5m/s,
3. The sampling position of the air temperature in the test room should be 15cm away from the air inlet of the dehumidifier, and it will not be affected by the exhaust gas of the dehumidifier under test or other heat sources.
Dehumidification capacity tolerance table: