ANSI AHAM AC-1 Air Cleaners Performance Test Chamber
Product Description:
The Air Cleaners Performance Test Chamber is mainly used to detect air purifiers and related household air purification devices.Test items include purification efficiency, clean air volume, purification energy efficiency, sterilization and antibacterial, negative ion concentration detection.
- Product Details
Introduction:
30 cubic meters air clecaner performance test chamber madee of 10mm float glass inner wall and special sealant with small adsorbability, assembled type design is easy for transportation due to the large inner design. The air purification system in the cabin is equipped with multi-functional air filters, which can remove not only particulate matter, but also chemical pollutants such as formaldehyde, benzene and ammonia. Moreover, the cabin has precise temperature and humidity control, good air tightness and low background concentration.
It is composed of 304 stainless steel and glass, including background control system, gas pollutant generator and testing instrument, temperature and humidity regulating system, etc.
Standard:
ANSI AHAM AC-1-2006 |
Test Method for Performance of Household Electric Power Cords or Indoor Air Cleaners |
GB/18801-2015 |
Air Purifier |
GB/18803-2002 |
Indoor Air Quality Standard |
IEC 62301:2005 |
Measurement of standby power in household appliances EPA Energy star United States Environmental Protection Agency Energy Star |
GB 4706.45-2008/IEC 60335-2-65:2005(Ed2.0) |
Electrical safety for household and similar purposes - Particular requirements for air purifiers |
Technical parameters:
Model |
HYQW-30B |
Testing Cabin(Inner) |
W3400 x D 3500 x H2500(mm) |
Outer Dimension |
W4900 x D 3900 x H3000(mm) |
Door |
W2000 x H 800(mm) |
Enviromental Temp. |
10℃~40℃ |
Temp.Deviation |
± 0.1℃ |
Temp.Fluctuation |
≦0.5℃ |
Temp.Uniformity |
≦2℃ |
Humidity Range |
RH 40~80% |
Humid.Accuracy |
1% |
Humid.Fluctuation |
≦ ±3% RH |
Humid.Uniformity |
≦ ±5% RH |
Air Exchange Rate |
0.5~50 times/second |
Air Flow |
0.1~0.5M/second |
Power Supply |
2000W,40~70HZ,0~300V(prepare by customer) |
Background Concentration of Formaldehyde |
PM2.5<1000ps/L;Formaldehyde < 0.01mg/m3 ; Methylbenzene ≦ 0.02mg/m3 ; |
Rate of Recovery |
≦ 30min |
Air Purification System |
500m3/H ~700m3/H stir fan,Dia.20cm, requests the distance 1.5m from the ground ; 0.4m from rear of chamber . |
Temp. Control Method |
BTH temp.balance |
Material |
l SUS# Stainless steel 304 ; 1mm ,floor 1.0mm l Glass cabin wall adopts stainless steel square tube as the reinforcing rib,and wall is made of 8 mm float glass. |
AHAM AC-1-2018 METHOD FOR MEASURING PERFORMANCE OF PORTABLE HOUSEHOLD ELECTRIC ROOM AIR CLEANERS
1.Temperature; R/H |
21±3℃; 40±5% |
2. Size of chamber |
10 ½ ft. x 12 ft. x 8 ft., 1008 ft3 [28.5㎥] |
3. Test particle |
|
1) Cigarette Smoke: 0.09 μm to 1.0 μm diameter. |
|
2) Air Cleaner Fine Fraction Test Dust: 0.5 μm to 3.0 μm. |
|
3) Pollen: 5μm to 11 μm, |
|
4. Measuring device |
|
1) Dust generator & Measuring system [TSI] |
|
2) Dust Generator [Model 3400 Fluidized Bed Aerosol Generator] |
|
3) Air Supply [Model 3074 - Air Supply System]-3400 Accessories |
|
4) Dust Neutralizer [Model 3012 Aerosol Neutralizer] |
|
5) Dust/Pollen Particle Counter [Aerodynamic Particle Sizer® (APS) Spectrometer - Model 3321 |
|
6) Cigarette Smoke Monitor[PMS Model TSI LAS 3340] |
|
7) Isokinetic Diluter: Custom Aerosol diluter - six to one dilution ratio at 1 cc/sec total flow rate. Aerosol Diluter 3302A |