30m3 purifier CADR test chamber (glass model)
machines to see if the test performance meets the standard.
- Product Details
Meet the standard:
GB/18801-2015
Air Purifier
GB/18803-2002
Indoor Air Quality Standard
IEC 62301:2005
Measurement of standby power in household appliances EPA Energy star United States Environmental Protection Agency Energy Star
GB 21551.3-2010
Antibacterial, sterilizing and purifying functions of household and similar electrical appliances-Special requirements for air purifiers
Technical parameter:
Serial number
Project
Content
A
Internal dimensions of environmental test chamber
3400D×3500W×2500Hmm,30m3。
Chamber dimensions
Box part:3600D×3700W×2950Hmm。
Crew section:约800D×700W×1500Hmm。
Door
Gate width0.8W*2.0H(Meter)
B
Temperature and humidity range
10℃~+60℃,40~70%RH。
Evenness
Temperature≤2℃; (no load).
Volatility
Temperature≤±0.5℃.
Instrument display accuracy
C
Ventilation rate
1~50 times/h.
D
Total installed capacity of equipment
1) Installation power: about 23kw
2) Actual operating power: related to the ambient
temperature and ventilation.
Preparation stage: about 18kw.
Constant stage: about 12kw.
Evacuation stage: about 5kw.
E
Equipment noise
≤75dBA(1m away from the device)
Equipment use conditions:
Serial number
Project
A
Ambient temperature:-10℃~+35℃, Relative humidity:20~80 RH
B
Ambient air background concentration:Formaldehyde less than 10μg/m3,
C
There should be no high concentration dust, corrosive gas and flammable and explosive atmosphere around.
D
Power supply: AC 380V±10 50Hz±5, three-phase five-wire system, grounding resistance ≤4 (Ω), meeting the
requirements of the installed capacity of the equipment.
Chamber structure:
Serial number
Project
Content
A
Test chamber
2.Floor (pre-embedded power/ground line), 1.0mm thick SUS304 stainless steel; top ceiling
1.0mm thick SUS304 stainless steel.
4.4 sets of 60W moisture-proof and explosion-proof lighting fixtures are installed in the
environmental test chamber.
6.An independent on-site mechanical pressure gauge (with an alarm device) shall be
installed in the chamber.
7.There are 2 internal explosion-proof and anti-corrosion power sockets, the strong and
weak electricity are separated, and the strong electricity is 20-30cm away from the bottom
of the chamber.
8.The end face seal of the fan side shaft of the circulating fan adopts imported sealed
bearings.
B
Chamber door
1. 1 fan door, the size of the door opening is 2000Hx800Wmm.
The sealing adopts tetraethylene strip + sealing strip (HBC1079 food-grade sealant,
which has passed the EU ROHS environmental protection standard, through the EU
REACH chemical regulations and standards, through the US FDA food hygiene standards).
2. The hinge can ensure the door opening angle ≥ 120 degrees.
Temperature: 0.1℃ Humidity: 0.1RH.