30m³ purifier glass environmental chamber
The purifier glass environment chamber mainly tests the purification
efficiency test of the air purifier on-hook, cabinet machine, vehicle-
mounted machine, and air duct machine to see whether the test
performance meets the standard.
- Product Details
Meet the standard:
GB/18801-2015
Air Purifier
GB/18803-2002
Indoor Air Quality Standard
GB 21551.3-2010
Antibacterial, sterilizing and purifying functions of household and similar electrical appliances-Special requirements for air purifiers
IEC 62301:2005
Measurement of standby power in household appliances EPA Energy star United States Environmental Protection Agency Energy Star
EPA Energy star United States Environmental Protection Agency Energy Star
GB 4706.45-2008/IEC 60335-2-65:2005(Ed2.0)
Electrical safety for household and similar purposes - Particular requirements for air purifiers
Technical parameters:
Serial number |
Project |
Content |
|
A |
Environmental test chamber
|
3400D×3500W×2500Hmm,30m3。 |
|
|
Carton size |
Box part:3600D×3700W×2950Hmm。 Crew section:约800D×700W×1500Hmm。 |
|
|
Door |
Gate width 0.8W*2.0H (meter) |
|
B |
Temperature and humidity range |
10℃~+60℃,40~70%RH。 |
|
|
Evenness |
Temperature≤2℃; (no load). |
|
|
Volatility |
Temperature≤±0.5℃。 |
|
|
Instrument display accuracy |
Temperature:0.1℃ humidity:0.1RH。 |
|
C |
Ventilation rate |
1~50 times/h. |
|
D |
Total installed capacity of equipment |
1) Installation power: about 23kw. 2) Actual operating power: related to the ambient temperature and ventilation. Preparation stage: about 18kw. Constant stage: about 12kw. Evacuation stage: about 5kw. |
|
E |
Equipment noise |
≤75dBA(1m away from the device) |
|
Conditions of use of the equipment: |
|||
Serial number |
Project |
||
A |
Ambient temperature:-10℃~+35℃, relative humidity:20~80 RH |
||
B |
Ambient air background concentration: formaldehyde is less than 10μg/m3, |
||
C |
There should be no high concentration dust, corrosive gas and flammable and explosive atmosphere around. |
||
D |
Power supply: AC 380V±10 50Hz±5, three-phase five-wire system, grounding resistance ≤4 (Ω), meeting the requirements of the installed capacity of the equipment. |
||
Chamber structure: |
|||
Serial number |
Project |
Content |
|
A |
Test chamber
|
1. The wall made of stainless steel square pass as reinforcing rib and 10mm
float glass 2. The floor (pre-embedded power/ground line) is made of 1.0mm thick SUS304 stainless steel; the top ceiling is 1.0mm thick SUS304 stainless steel. 3.Ground bearing ≥500Kg/m2. 4.4 sets of 60W moisture-proof and explosion-proof lighting fixtures are installed in the environmental test chamber. 5.Corrosion-proof and explosion-proof power sockets need to be reserved. 6.An independent local mechanical pressure gauge (with an alarm device) shall be installed in the chamber. 7.There are 2 internal explosion-proof and anti-corrosion power sockets, strong and weak electricity are separated, and the strong electricity is 20-30cm away from the bottom of the chamber. 8.The end face seal of the fan side shaft of the circulating fan adopts imported sealed bearings. 9.The cabin is provided with a pressure balance port. |
|
B |
Chamber door |
1. 1 door, the size of the door opening is 2000Hx800Wmm. The sealing adopts tetraethylene strip + sealing strip (HBC1079 food-grade sealant has passed the EU ROHS environmental protection standard, passed the EU REACH chemical regulation standard, and passed the US FDA food hygiene standard). 2. The hinge can ensure that the opening angle of the door is ≥120 degrees. |